Join Us!
Panacoustics Ltd Acoustics Consultants, Cyprus, Tel: 25-822816
  • Home
  • About
  • Services
  • Projects
    • Performing Spaces
    • Small Events Spaces
    • Commercial & Medical Spaces
    • Residential Spaces
    • Educational Spaces
    • Broadcasting & Recording Studios
    • Cinemas and Home Theatres
    • Recreational
    • Places of Worship
    • Entertainment & Hospitality
    • Environmental Noise Impact Assessment
    • Noise Control
    • Sound Insulation Measurements
    • Specialised Projects
  • Products
    • Sound Level Meters >
      • Cirrus Research
      • Castle Group
      • SVANTEK
      • CESVA Sound Level Meters
      • RION Sound Level Meters
      • BSWA Sound Level Meters
    • Vibration Meters >
      • Cirrus REVO Vibration Meter
      • Castle Vibration Meters
      • Svantek Vibration Meters
      • CESVA Vibrometers
      • RION Vibration Meters
    • Dosimeters >
      • Cirrus Research Noise Dosimeters
      • Svantek Noise Dosimeters
      • Cesva Noise Dosimeters
      • soundBadge
    • Noise Monitoring >
      • Sonitus Systems Noise Monitoring Solutions
      • CIRRUS Environmental Noise Kits for the Optimus Sound Level Meters
      • SVANTEK Noise and Vibration Monitoring Systems
      • CESVA TA120 Noise measuring sensor for Smart Solutions
      • SCS 9077 Noise Monitoring Station
      • RION NA 37 Environmental Sound Monitor(
    • Sound Sources & Tapping Machines >
      • Infra-QSources Noise Sources
      • CESVA Sound Sources & Tapping Machines
      • Ntek Building Acoustic Equipment
      • BSWA Sound Sources
    • Noise Alert Systems >
      • SoundEar Noise Alert Systems
    • Multi Channel Systems >
      • RIONOTE Multi-function Measuring System
      • RION SA-02 Multi Channel Signal Analyzer
    • Sound Limiters >
      • DATEQ Audio Technologies
      • CESVA Sound Level Logger-Limiters
    • Calibrators >
      • RION Calibrators
      • SVANTEK Calibrators
      • CESVA Calibrators
      • CIRRUS Calibrators
      • Castle Calibrators
    • Microphones & Accelerometers >
      • RION Microphones & Accelerometers
      • CESVA Microphones & Accelerometers
      • SVANTEK Microphones & Accelerometers
      • BSWA Microphones & Peamplifiers
    • Materials & Special Testing >
      • SCS 902A Testing Devices
      • BSWA SW Series Impedance Tubes
      • TestSens SOUNDTUBE
      • RION Acoustical Volume & Capacity Meter
    • Audiology Instruments
    • Industrial Enclosures
    • Cambridge Sound Masking Systems >
      • QTPRO Sound Masking Systems
  • Software
  • Contact
  • Home
  • About
  • Services
  • Projects
    • Performing Spaces
    • Small Events Spaces
    • Commercial & Medical Spaces
    • Residential Spaces
    • Educational Spaces
    • Broadcasting & Recording Studios
    • Cinemas and Home Theatres
    • Recreational
    • Places of Worship
    • Entertainment & Hospitality
    • Environmental Noise Impact Assessment
    • Noise Control
    • Sound Insulation Measurements
    • Specialised Projects
  • Products
    • Sound Level Meters >
      • Cirrus Research
      • Castle Group
      • SVANTEK
      • CESVA Sound Level Meters
      • RION Sound Level Meters
      • BSWA Sound Level Meters
    • Vibration Meters >
      • Cirrus REVO Vibration Meter
      • Castle Vibration Meters
      • Svantek Vibration Meters
      • CESVA Vibrometers
      • RION Vibration Meters
    • Dosimeters >
      • Cirrus Research Noise Dosimeters
      • Svantek Noise Dosimeters
      • Cesva Noise Dosimeters
      • soundBadge
    • Noise Monitoring >
      • Sonitus Systems Noise Monitoring Solutions
      • CIRRUS Environmental Noise Kits for the Optimus Sound Level Meters
      • SVANTEK Noise and Vibration Monitoring Systems
      • CESVA TA120 Noise measuring sensor for Smart Solutions
      • SCS 9077 Noise Monitoring Station
      • RION NA 37 Environmental Sound Monitor(
    • Sound Sources & Tapping Machines >
      • Infra-QSources Noise Sources
      • CESVA Sound Sources & Tapping Machines
      • Ntek Building Acoustic Equipment
      • BSWA Sound Sources
    • Noise Alert Systems >
      • SoundEar Noise Alert Systems
    • Multi Channel Systems >
      • RIONOTE Multi-function Measuring System
      • RION SA-02 Multi Channel Signal Analyzer
    • Sound Limiters >
      • DATEQ Audio Technologies
      • CESVA Sound Level Logger-Limiters
    • Calibrators >
      • RION Calibrators
      • SVANTEK Calibrators
      • CESVA Calibrators
      • CIRRUS Calibrators
      • Castle Calibrators
    • Microphones & Accelerometers >
      • RION Microphones & Accelerometers
      • CESVA Microphones & Accelerometers
      • SVANTEK Microphones & Accelerometers
      • BSWA Microphones & Peamplifiers
    • Materials & Special Testing >
      • SCS 902A Testing Devices
      • BSWA SW Series Impedance Tubes
      • TestSens SOUNDTUBE
      • RION Acoustical Volume & Capacity Meter
    • Audiology Instruments
    • Industrial Enclosures
    • Cambridge Sound Masking Systems >
      • QTPRO Sound Masking Systems
  • Software
  • Contact

CESVA
​Noise Monitoring platform

CESVA Noise Monitoring Platform

Sensing of Smart Cities, permanent monitoring of road and port infrastructures, industrial activities, work control, monitoring of noise in concerts, festivals, noise maps generation, etc.

​Local administrations are increasingly more committed to the control noise. For this purpose, strategic noise maps are produced and action plans are implemented. 


CESVA has a noise measuring sensor (TA120) and the  on-line noise monitoring platform (NoisePlatform). Noiseplatform facilitates the deployment of a network of sensors in the studied areas in order to collect and store real-time noise data level.

The continuous generation of reliable data for monitoring action plans enables the rapid assessment of these plans' effectiveness and the taking of decisions regarding their continuance, thus saving time and economic resources.    
Picture

TA120

Noise measuring sensor for Smart Solutions​
​The TA120 sensor combines the precision of a Class 1 sound level meter, maximum protection of  an outdoor kit and full connectivity with  CESVA NoisePlatform and open source platforms.

  • Continuous measurement (24h / 7d) with class 1 accuracy according to IEC 61672-1
  • Protection against external agents with an outdoor kit: wind, rain, birds and insects
  •  IP65 protection against dust and water
  • Compatible with NoisePlatform Platform  and various open source platform for sensors connectivity
  • Light weighted, small sized and easy to integrate into the urban furniture 
  • Powered by mains, POE (Power over Ethernet), 12 VDC (Solar panels, external batteries)
  • Communication by Ethernet (RJ45), loop 4-20mA*, Wi-Fi*, 3G modem*  (*Optional) 
  •  Smart cities sensing, noise surveillance networks (permanent monitoring), protection of quiet areas, displaying noise levels in real time, etc.
Picture

Main Features

Picture

Precision and reliability

The TA120 sensor measures, according to IEC 61672-1 class 1, the equivalent continuous sound level with A frequency weighting in a single range of 35-120 dBA. 

The integration time is configurable between 1s* and 60min and the measurement is continuous 24 hours / 7 days a week. The TA120 can be checked quickly with an acoustic calibrator (IEC 60942).

*Integration times shorter than 10s require high-speed networks.

Fully integrated into the urban landscape

The TA120 is very easy to install on street lights, marquees, billboards, shelters, kiosks and advertising posts and requires minimum annual maintenance.

The TA120 is powered through the mains, POE, 12 VDC voltage or through the urban lightning network with battery backup. The BA120 optional battery guarantees the sufficient duration and charging time to complete annual cycles.
Picture

Picture

Maximum protection

The outdoor kit of the TA120 sensor allows respecting Class 1 measurement precision, to achieve a high protection against external agents such as wind, rain, birds and insects; reaching IP65 according to IEC 60529. 

The TA120 ensures proper acoustic performance at temperatures between -10 and +50° C.
The materials used in the manufacture of TA120 ensure a long life cycle of the sensor.

Connectivity with IoT platforms

The TA120 sensor is fully integrated into different platform connectivity sensors as NoisePlatform,  Sentilo, Telefonica, SmartyPlanet, etc. The communication can be performed through:
  • Ethernet (LAN)
  • current loop 4-20 mA*
  • Wi-Fi module* 
  • modem 3G / GPRS module* 
(*Optional)

The TA120 uses HTTP and HTTPS (secure connection) with UL2.0 (UltraLight 2.0) format, JSON (Java Script Object Notation) format, or Other (consult).
Picture

Picture

CESVA NoisePlatform

NoisePlatform is an on-line platform that displays and dynamically analyses, in real time, the noise measured by a mixed network of sensors and terminals that can monitor the entire area affected by noise-generating activities. 
More info
Picture

WHY NOISEPLATFORM?

NoisePlatform heralds a step forward in noise monitoring. Hitherto, monitoring projects were usually implemented with a single terminal that was transported to different sites due to its high cost. 

This meant that the information available was not simultaneous and the terminal installation costs were higher. NoisePlatform works with a mixed network of sensors and terminals that does away with all these obstacles to deliver continuous and multi-point noise monitoring, thanks mainly to the low cost of its sensors and minimum maintenance cost of the platform.
 

In addition, NoisePlatform is a precise, reliable and secure system (Class 1 measuring precision, reliability in data transmission, secure server certified with 256-bit SSL encryption) and 100% online (access, display and analysis).

Supported Platforms

Picture
Sentilo
Sentilo is an open source sensor and actuator platform designed to fit in the Smart City architecture of any city who looks for openness and easy interoperability. It’s built, used, and supported by an active and diverse community of cities and companies that believe that using open standards and free software is the first smart decision a Smart City should take.
Picture
Telefonica
A Smart City is an environment that involves many technologies and multiple agents: from sensors scattered throughout the whole city (to collect any kind of data: traffic, water, energy) to the mobile devices of the citizens; from mayors to traders. All this data must be managed by a platform that centralises and processes it.

​CESVA Sensor Manager

CESVA Sensor Manager is the communications software for CESVA noise sensors. To communicate with the noise sensor, install the CESVA USB Drivers and the CESVA Sensor Manager. 

Compatible with Windows 7, Windows 8, Windows 8.1 and Windows 10.
Picture
Sensor information and adjustment
When performing the communication, CESVA Sensor Manager displays the information for the TA120 sensor and allows check and adjust the sensitivity of the sensor, if necessary.  
Advanced mode: Parameters Settings
CESVA Sensor Manager allows, after the password is entered, set the communication parameters depending on the different communication options: Server, Ethernet port, modem 3G, Wi-Fi or current loop.
Picture

​Communication Options

Picture
MR120
Module for data transmission 3G/GPRS
Picture
WF120
Module for data transmission
​Wi-Fi 
​
Picture
CL120
Module for current loop  (4-20mA)

​Optional accessories

Picture
BA120
Internal lithium battery for day-time operation with urban lightning network
Picture
TS120
Kit for sensor support. Includes: support plate, 2 large plastic cable ties, 4 washers, 4 glower washers and 4 nuts. 

​

Data Sheet & Product Information

Table of Standards

Picture
IEC 60529:2013     IP65 protection degree
CE                          Complies with 73/23/CEE and CEM 89/336/CEE low-tension                                     regulations, the latter amended by 93/68/CEE.
Acoustic instrumentation guide
File Size: 1080 kb
File Type: pdf
Download File

Services

Architectural Acoustics
Building Acoustics
Room Acoustics
Noise Control
Environmental Acoustics
Electroacoustics
Sound Insulation Measurements
Noise Monitoring
Impact Noise Assessments

Products

Sound Level Meters
Vibration Meters/Analyzers
Dosimeters - Noise At Work
Noise Monitoring Systems
Sound Sources - Building Acoustics
Noise Alert Systems
Multi Channel Systems
Sound Limiters
Calibrators
Microphones & Accelerometers
Material Testing
Sound Masking Systems
Audiology  Booths & Instruments 
Industrial Enclosures
Acoustic Panels
Ready-Made Studios
Software

Contact

P.O. Box 51443
Limassol 3505
Cyprus
T: +357 25 822816
F: +357 25 822817
​E: info@panacoustics.com
​

Events

© COPYRIGHT 2023 Panacoustics Ltd. ALL RIGHTS RESERVED.