Join Us!
Panacoustics Ltd Acoustics Consultants, Cyprus, Tel: 25-822816
  • Home
  • About
  • Services
    • Online Acoustics Engineering and Consulting Services
  • Projects
    • Performing Spaces
    • Small Events Spaces
    • Commercial & Medical Spaces
    • Residential Spaces
    • Educational Spaces
    • Broadcasting & Recording Studios
    • Cinemas and Home Theatres
    • Recreational
    • Places of Worship
    • Entertainment & Hospitality
    • Environmental Noise Impact Assessment
    • Noise Control
    • Sound Insulation Measurements
    • Specialised Projects
  • Products
    • Sound Level Meters >
      • Cirrus Research
      • Castle Group
      • SVANTEK
      • CESVA Sound Level Meters
      • RION Sound Level Meters
      • BSWA Sound Level Meters
    • Vibration Meters >
      • Cirrus REVO Vibration Meter
      • Castle Vibration Meters
      • Svantek Vibration Meters
      • CESVA Vibrometers
      • RION Vibration Meters
    • Dosimeters >
      • Cirrus Research Noise Dosimeters
      • Svantek Noise Dosimeters
      • Cesva Noise Dosimeters
      • soundBadge
    • Noise Monitoring >
      • Sonitus Systems Noise Monitoring Solutions
      • CIRRUS Environmental Noise Kits for the Optimus Sound Level Meters
      • SVANTEK Noise and Vibration Monitoring Systems
      • CESVA TA120 Noise measuring sensor for Smart Solutions
      • SCS 9077 Noise Monitoring Station
      • RION NA 37 Environmental Sound Monitor(
    • Sound Sources & Tapping Machines >
      • Infra-QSources Noise Sources
      • CESVA Sound Sources & Tapping Machines
      • Ntek Building Acoustic Equipment
      • BSWA Sound Sources
    • Noise Alert Systems >
      • SoundEar Noise Alert Systems
    • Multi Channel Systems >
      • RIONOTE Multi-function Measuring System
      • RION SA-02 Multi Channel Signal Analyzer
    • Sound Limiters >
      • DATEQ Audio Technologies
      • CESVA Sound Level Logger-Limiters
    • Calibrators >
      • RION Calibrators
      • SVANTEK Calibrators
      • CESVA Calibrators
      • CIRRUS Calibrators
      • Castle Calibrators
    • Microphones & Accelerometers >
      • RION Microphones & Accelerometers
      • CESVA Microphones & Accelerometers
      • SVANTEK Microphones & Accelerometers
      • BSWA Microphones & Peamplifiers
    • Materials & Special Testing >
      • SCS 902A Testing Devices
      • BSWA SW Series Impedance Tubes
      • TestSens SOUNDTUBE
      • RION Acoustical Volume & Capacity Meter
    • Audiology Instruments
    • Industrial Enclosures
    • Eckel Acoustic Panels
    • Ready-Made Studios
    • Cambridge Sound Masking Systems >
      • QTPRO Sound Masking Systems
  • Software
  • Contact
  • Home
  • About
  • Services
    • Online Acoustics Engineering and Consulting Services
  • Projects
    • Performing Spaces
    • Small Events Spaces
    • Commercial & Medical Spaces
    • Residential Spaces
    • Educational Spaces
    • Broadcasting & Recording Studios
    • Cinemas and Home Theatres
    • Recreational
    • Places of Worship
    • Entertainment & Hospitality
    • Environmental Noise Impact Assessment
    • Noise Control
    • Sound Insulation Measurements
    • Specialised Projects
  • Products
    • Sound Level Meters >
      • Cirrus Research
      • Castle Group
      • SVANTEK
      • CESVA Sound Level Meters
      • RION Sound Level Meters
      • BSWA Sound Level Meters
    • Vibration Meters >
      • Cirrus REVO Vibration Meter
      • Castle Vibration Meters
      • Svantek Vibration Meters
      • CESVA Vibrometers
      • RION Vibration Meters
    • Dosimeters >
      • Cirrus Research Noise Dosimeters
      • Svantek Noise Dosimeters
      • Cesva Noise Dosimeters
      • soundBadge
    • Noise Monitoring >
      • Sonitus Systems Noise Monitoring Solutions
      • CIRRUS Environmental Noise Kits for the Optimus Sound Level Meters
      • SVANTEK Noise and Vibration Monitoring Systems
      • CESVA TA120 Noise measuring sensor for Smart Solutions
      • SCS 9077 Noise Monitoring Station
      • RION NA 37 Environmental Sound Monitor(
    • Sound Sources & Tapping Machines >
      • Infra-QSources Noise Sources
      • CESVA Sound Sources & Tapping Machines
      • Ntek Building Acoustic Equipment
      • BSWA Sound Sources
    • Noise Alert Systems >
      • SoundEar Noise Alert Systems
    • Multi Channel Systems >
      • RIONOTE Multi-function Measuring System
      • RION SA-02 Multi Channel Signal Analyzer
    • Sound Limiters >
      • DATEQ Audio Technologies
      • CESVA Sound Level Logger-Limiters
    • Calibrators >
      • RION Calibrators
      • SVANTEK Calibrators
      • CESVA Calibrators
      • CIRRUS Calibrators
      • Castle Calibrators
    • Microphones & Accelerometers >
      • RION Microphones & Accelerometers
      • CESVA Microphones & Accelerometers
      • SVANTEK Microphones & Accelerometers
      • BSWA Microphones & Peamplifiers
    • Materials & Special Testing >
      • SCS 902A Testing Devices
      • BSWA SW Series Impedance Tubes
      • TestSens SOUNDTUBE
      • RION Acoustical Volume & Capacity Meter
    • Audiology Instruments
    • Industrial Enclosures
    • Eckel Acoustic Panels
    • Ready-Made Studios
    • Cambridge Sound Masking Systems >
      • QTPRO Sound Masking Systems
  • Software
  • Contact

 TM003 Tapping Machine

BSWA TM003 Tapping Machine

TM003 Tapping Machine is a rugged, self-contained sound source for making footfall noise measurements to the latest international standards (ISO140, EN 20140, ASTM E492, GB J75-84, etc.).

Key features of TM003

  • Five 500g hammers with falling heights of 40mm
  • 10 impacts per second
  • Solid aluminum base for stable operation
  • Reduced machine noise via belt drive
  • Long lasting industrial drive motor
  • No metal-to-metal moving parts resulting in less wear and smooth operation
  • 24V DC power supply via a 220V/110V AC /DC adaptor.
  • Remote control with an operating distance of 2 floors.
Picture
Picture

Data Sheet & Product Information

Picture

Specifications - Technical Information

Standard Items Included:
  • TM003 x1,Power Supply Adaptor x1,Remote Controlx1,User’s Manual x1,4mm L-type wrenchx1
Standards:
  • ISO140, BS5821, GBJ75, ASTM492, EN20140
Hammers:
  • Five in line, 100 mm between each hammer, single hammer weight 500±10g
Impact Frequency:
  • Each hammer operates at 2Hz; tapping frequency for unit is 10±0.3Hz
Impact Forces:
  • Equivalent free-fall height of hammers 40 mm
Motor:​
  • Stepper Motor
Dimensions:
  • 580 '145 '275 mm
Power supply:
  • 24V DC power supply via a 220V/110V AC /DC adaptor
O / Temperature:
  • -10℃ ~ 50℃
O / Humidity:
  • 0 ~ 98% RH
Carrying Case:
  • 700 mm × 400 mm × 260 mm
Fuse:
  • 0.5A
Net Weight:
  • 10 kg (15 kg including the case)

Services

Architectural Acoustics
Building Acoustics
Room Acoustics
Noise Control
Environmental Acoustics
Electroacoustics
Sound Insulation Measurements
Noise Monitoring
Impact Noise Assessments
​Online Consultancy Services

Products

Sound Level Meters
Vibration Meters/Analyzers
Dosimeters - Noise At Work
Noise Monitoring Systems
Sound Sources - Building Acoustics
Noise Alert Systems
Multi Channel Systems
Sound Limiters
Calibrators
Microphones & Accelerometers
Material Testing
Sound Masking Systems
Audiology  Booths & Instruments 
Industrial Enclosures
Acoustic Panels
Ready-Made Studios
Software

Contact

P.O. Box 51443
Limassol 3505
Cyprus
T: +357 25 822816
F: +357 25 822817
​E: info@panacoustics.com
​

Events

© COPYRIGHT 2020 Panacoustics Ltd. ALL RIGHTS RESERVED.