Optimus Green Sound Level Meters
|
A Total Solution for Occupational and Environmental Noise Measurements
Optimus Green Sound Level Meters
Do you need an all-in-one solution for your noise measurements? The Optimus Green gives you all the noise data you could possibly need for both environmental and occupational noise.
By measuring every parameter you need simultaneously, the Optimus Green records everything in one measurement. There's no risk of choosing the wrong function or missing any data. All you need to do to get going is switch on, calibrate and start. It's that simple.
All of your measurement data displays on the large OLED screen. You'll be able to see straight away if there are any noise issues that need further investigation. You can easily navigate screens during measurements to see the data you need.
Whether it's environmental noise monitoring, detailed noise analysis using audio recording or workplace noise measurements, the Optimus Green has you covered.
Do you need an all-in-one solution for your noise measurements? The Optimus Green gives you all the noise data you could possibly need for both environmental and occupational noise.
By measuring every parameter you need simultaneously, the Optimus Green records everything in one measurement. There's no risk of choosing the wrong function or missing any data. All you need to do to get going is switch on, calibrate and start. It's that simple.
All of your measurement data displays on the large OLED screen. You'll be able to see straight away if there are any noise issues that need further investigation. You can easily navigate screens during measurements to see the data you need.
Whether it's environmental noise monitoring, detailed noise analysis using audio recording or workplace noise measurements, the Optimus Green has you covered.
Why Choose Optimus Green?
Downloading Your Data is SimpleWe'll include our NoiseTools noise analysis software with all versions of the Optimus Green, so you can keep a store and analyse your measurements.
You can upgrade this instrument to a more advanced version of the Optimus Green at any time, future-proofing your investment. Which Optimus Green is right for you? |
There are 8 versions of the Optimus Green Sound Level Meters, 4 with Class 2 performance and 4 with Class 1 performance.
The table below shows the different versions and options available with each instrument.
You can also use our interactive Optimus Product Selector to find the best instrument for you.
The table below shows the different versions and options available with each instrument.
You can also use our interactive Optimus Product Selector to find the best instrument for you.
More Information
Data Sheet & Product Information |
Specifications - Technical InformationApplicable Standards
EC 61672-1:2013 Class 1 or Class 2 IEC 61672-1:2002 Class 1 or Class 2 Group X IEC 60651:2001 Type 1 I or Type 2 I IEC 60804:2000 Type 1 or Type 2 IEC 61252:1993 Personal Sound Exposure Meters ANSI S1.4 -1983 (R2006), ANSI S1.43 - 1997 (R2007) ANSI S1.25:1991 1:1 & 1:3 Octave Band Filters to IEC 61260 & ANSI S1.11-2004 Type Approvals for Class 1 Instruments LNE-25387-1 IEC 61672-1:2013 NF EN 61672-1:2014 IEC 61260:1996 NF EN 61260:1996 LNE-25387-0 EN 61672-1:2003 PTB-1.53-4052960 DIN EN 61672-1:2003-10 DIN EN 61672-2:2004-08 DIN 45657:2005-03 Applus+ 02-001-B-62/13-R UNE-EN 61672-1:2005 Microphone Class 1 MK:224 pre-polarized, Class 2 MK:216 pre-polarized Microphone Preamplifier MV:200 Removable Preamplifier (All versions) Total Measurement Range: 20dB to 140dB RMS Single Range Noise Floor: <18dB(A) Class 1, <21dB(A) Class 2 Frequency Weightings RMS & Peak : A, C, & Z Measured Simultaneously Frequency Bands: 10 x 1:1 Octave Bands (31.5Hz to 16kHz, A, B & C variants) Frequency Bands: 36 x 1:3 Octave Bands Measured (6.3Hz to 20kHz, B & C variants) Frequency Bands: 33 x 1:3 Octave Bands Displayed (12.5Hz to 20kHz, B & C variants) Additional Metrics: LAeq LF (20Hz to 200Hz) & Leq LF (20Hz to 200Hz) Time Weightings Fast, Slow & Impulse Measured Simultaneously Display High resolution OLED display. Ambient light sensor & illuminated keypad Memory 4GB with 32GB factory fit option AuditStore Measurement verification data stored in secure memory Time History Data Rates (Global settings) 10ms, 62.5ms, 125ms, 250ms, 1/2 sec, 1 sec, 2 sec (User selectable) VoiceTag Audio Recording Up to 30 seconds of audio notes with each measurement Bluetooth BLE compatible with Android and iOS devices. Cirrus mobile applications available from Google Play and the App Store Acoustic Fingerprint Audio Recording Off, Manual, Threshold Triggered, Advanced Trigger User options: Studio Quality - 96kHz/32bit WAV format Standard quality - 16kHz/16bit WAV format Pre-Trigger function Integrators Three simultaneous "virtual" noise meters. Integrator 1 is preset to Q3 for Leq functions. Integrators 2 & 3 can be configured with the following: Exchange Rate: 3, 4 or 5 dB Threshold: 70dB to 120dB (1 dB steps) Time Weighting: None or Slow Criterion Level: 70dB to 120dB (1 dB steps) Criterion Time: 1 to 12 hours in 1 hour steps Integrator Quick settings EU, OSHA HC & OSHA NC, OSHA HC & ACGIH, MSHA HC & MSHA EC, Custom 1 & Custom 2 Ln Statistical Values 14 independent statistical Ln values calculated from 1/16th LAF 7 preset to L1.0, L5.0, L10.0, L50.0, L90.0, L95.0 & L99.0 7 user defined Ln values. CR:172C & CR:171C allow for an additional 14 Ln values with independent time and frequency weighting. Measurement control Measurement control with user selectable duration of manual, 1 min, 5 min, 10 min, 15 min,30 mins, 1 hour, Lden Automatic Synchronisation & Repeat Pause & Back Erase with user selectable duration Dimensions Size: 283mm x 65mm x 30mm Weight: 300gms/10oz Batteries 4 x AA Alkaline Battery life Typically 12 hours with Alkaline AA Typically 20 hours with Lithium AA Non-Rechargeable Battery life is dependent upon the battery type, quality & screen brightness Connections USB Type B to PC AC & DC Output via ZL:174 (2 x Phono, 1m) Multi-pin IO for external power via ZL:171 cable (2.1mm socket) External Power: 5v-15v via MultiIO socket via ZL:171 cable (2.1mm socket) Tripod Mount 1/4" Whitworth socket Case Material: High Impact ABS-PC with soft touch back & keypad |
Environmental
Temperature: Operating -10°C to +50°C, Storage -20°C to +60°C Humidity: Up to 95% RH Non Condensing Electromagnetic performance IEC 61672-1:2002 & IEC 61672-2:2003 Except where modified by EN 61000-6-1:2007 & EN 61000-6-1:2007 Language options English, French, German, Spanish. Other language options may be available Software Support NoiseTools Download, Configuration & Analysis software supplied as standard. Compatible with Microsoft Windows XP, Vista, 7 & 8 (32bit & 64bit) Measurement Functions CR:1720 & CR:1710 Displayed Functions LXY, LXYMax, LXYMin, LXeq, LCPeak, LAPeak, LZPeak, LCeq-LAeq, LXE, LAIeq Graph of Short LAeq, LCPeak Integrators 2 & 3: TWA, Dose%, Est Dose% Measurement Run Time Integrators 2 & 3: TWA, Dose%, Est Dose% 14 Statistical Ln values Stored Functions LXYMax & Time History of LXYMax LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq Time History of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq Integrators 2 & 3: LAVG , TWA. %Dose Time History of LAVG Ln Values: 14 independent statistical values Audio recording during measurement CR:172A & CR:171A Displayed Functions LXY, LXYMax, LXYMin, LXeq, LCPeak, LAPeak, LZPeak, LCeq-LAeq, LXE, LAIeq Graph of Short LAeq, LCPeak Integrators 2 & 3: TWA, Dose%, Est Dose% Real-Time 1:1 Octave Bands (Graphical & Numeric) NR & NC values & curves Measurement Run Time Integrators 2 & 3: TWA, Dose%, Est Dose% 14 Statistical Ln values Stored Functions LXYMax & Time History of LXYMax LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq Time History of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq Integrators 2 & 3: LAVG , TWA. %Dose Time History of LAVG 1:1 Octave Bands:Overall Leq & Leq Time History for each band, NR & NC values & curves Ln Values: 14 independent statistical values Audio recording during measurement CR:172B & CR:171B Displayed Functions LXY, LXYMax, LXYMin, LXeq, LCPeak, LAPeak, LZPeak, LCeq-LAeq, LXE, LAIeq Graph of Short LAeq, LCPeak Integrators 2 & 3: TWA, Dose%, Est Dose% Real-Time 1:1 Octave Bands (Graphical & Numeric) Real-Time 1:3 Octave Bands (Graphical & Numeric) NR & NC values & curves Measurement Run Time Integrators 2 & 3: TWA, Dose%, Est Dose% Leq LF (20Hz to 200Hz) 14 Statistical Ln values Stored Functions LXYMax & Time History of LXYMax LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq Time History of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq Integrators 2 & 3: LAVG , TWA. %Dose Time History of LAVG 1:1 & 1:3 Octave Bands:Overall Leq & Leq Time History for each band, NR & NC values & curves Ln Values: 14 independent statistical values Audio recording during measurement CR:172C & CR:171C Displayed Functions LXY, LXYMax, LXYMin, LXeq, LCPeak, LAPeak, LZPeak, LCeq-LAeq, LXE, LAIeq Graph of Short LAeq, LCPeak Integrators 2 & 3: TWA, Dose%, Est Dose% Real-Time 1:1 Octave Bands (Graphical & Numeric) Real-Time 1:3 Octave Bands (Graphical & Numeric) Tonal Noise Detection in 1:3 Octave Bands NR & NC values & curves Measurement Run Time Integrators 2 & 3: TWA, Dose%, Est Dose% Leq LF (20Hz to 200Hz) 28 Statistical Ln values Stored Functions LXYMax & Time History of LXYMax LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq Time History of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq Integrators 2 & 3: LAVG , TWA. %Dose Time History of LAVG 1:1 & 1:3 Octave Bands:Overall Leq & Leq Time History for each band, NR & NC values & curves Tonal Noise Detection in 1:3 Octave Bands Ln Values: 28 independent statistical values Audio recording during measurement where x=A ,C ,Z; y= F, S, I Other functions may calculated by the NoiseTools software and displayed on download. |